Newer
Older
gnexus-book / 10-systems / hardware / hp-proliant-dl380-g6.md

owner: gmikcon status: active last_reviewed: 2026-10-30 review_interval: 90d confidence: high

source_of_truth: ssh-libvirt

HP ProLiant DL380 G6

Physical server in the home infrastructure.

Role

  • Virtualization host.
  • Runs KVM/QEMU virtual machines through system libvirt.
  • Managed through Cockpit and virsh.

Access

  • Cockpit: https://192.168.1.130:9090/system
  • SSH user known for administration: bserv
  • Secret values are not stored in this repository.

Operating System

  • OS: Ubuntu 22.04.4 LTS
  • Kernel observed: 5.15.0-176-generic

Virtualization

  • Stack: KVM/QEMU through libvirt.
  • Libvirt connection: qemu:///system
  • Tools observed: virsh, cockpit-machines
  • Active services observed: libvirtd, virtlogd

See virtual machine inventory.

Storage controller (hpsa) — known failure mode (2026-10-30)

The HP Smart Array controller (hpsa driver, PCI 0000:04:00.0) can stall and reset its logical volumes (RAID-1(+0), SSDSmartPathCap). During a reset the whole volume freezes for tens of seconds; all VM disks on the affected volume stall, guest load1 spikes to 2-10x cores with CPU near 0% (classic D-state / I/O-wait signature), and network services behind those VMs time out.

Incident 2026-10-30 13:06-13:15 UTC

  • 13:06:17 first hpsa logical-volume reset (scsi 0:1:0:0).
  • 13:10:08-13:15:16 reset series on both logical volumes (scsi 0:1:0:0 and 0:1:0:1), each "reset logical completed successfully" 15-70 s later.
  • Panel load_high events in the same window: files #36 (2.5x), gnsynapse (3.5x), gnauth (2.2x), gncreds (10.5x), hard-panel-176 (9.9x), internal-proxy cpu_high 93%; hive registry (192.168.1.168:8087) ReadTimeout ~13:10-13:13.
  • bserv host load1 peaked ~100 (5-min avg) with CPU mostly idle; no D-state processes after the stall; no physical-drive failures in the kernel log.
  • Self-recovered by ~13:15:30 UTC; no VM restarts needed; all VMs stayed running.
  • Coincidence, not cause: an ollama pull of a ~92 GB model (blob 92907148363e) was running on bserv 13:07-13:11 and stalled its download parts during the resets; the pull did not survive (no active pull after the incident). Root disk had only 40G free, so the pull could not complete anyway.

Triage playbook

  1. Confirm the signature: journalctl -k | grep hpsa — look for "resetting logical ... reset logical completed successfully".
  2. Check whether resets are ongoing: journalctl -k --since "<now-10m>" | grep -c hpsa.
  3. Check VM states: virsh list --all (VMs normally keep running through a reset; only their I/O stalls).
  4. If resets repeat within hours/days: suspect the controller or its cache battery; plan a maintenance window (firmware update via ssacli/iLO, or controller replacement). ssacli/hpssacli are NOT installed on bserv — install ssacli before the next maintenance window.
  5. Escalate to the owner only if resets repeat or a physical drive reports errors; single self-recovering episodes need no notification (no-noise policy).

History

  • 2026-10-25: 1 hpsa reset (single, self-recovered).
  • 2026-10-30: 9 resets in ~9 minutes (the incident above).